As a result, the performance requirements for houses are increasing, requiring all new houses to be much more efficient than previously.
The jump from 3.5 Stars to 5 Stars is roughly 35% less MJ/m². From our experience about 90% of houses will require design changes to achieve 5 Stars, about 60% will require some design changes to achieve 4.5 Stars, and about 30% for 4 Stars. We currently have about 10% of houses that require some effort to get 3.5 Stars and most of these will not achieve 4 Stars without less glass.
Below are the specifics of the changes happening.
For building designs substantially completed BEFORE 1 March 2009, the Building Code of Australia BCA2008 applies:
For Class 1 and attached Class 10a the Queensland Variation to BCA2005 Part 2.6 applies:
either DTS2005 Part 3.12 OR Verification Method V2.6.2.1 (House Star Rating)
The Star Rating assessments can be performed either by First Generation (e.g. BERS Version 3.2) or Second Generation (e.g. BERS Pro), though Second Generation is strongly preferred by Building Codes Queensland (and us).
For building designs substantially completed BETWEEN 1 March 2009 and 30 April 2009, the Building Code of Australia BCA2008 applies without Queensland variations, but with QDC MP4.1 Acceptable Solutions A1 (the new parts). The BCQ Newsflash 355 applies here (copy available from www.dip.qld.gov.au/resources/newsletter/newsflash-355.pdf ).
For Class 1 and attached Class 10a buildings
either DTS2008 Part 3.12 (tighter glazing than DTS2005)
OR Verification Method V2.6.2.1 (House Star Rating using Second Generation software only)
OR Verification Method V2.6.2.2 (Reference Building using suitable thermal calculation software)
For building designs substantially completed FROM 1 May 2009, the Building Code of Australia BCA2009 applies, with MP4.1 Acceptable Solution A1(d) as above for Class 1 and attached Class 10a buildings.
Please spread the word: Class 1 buildings (houses) need to be more Energy Efficient than before 1 March 2009.
Below are some recommendations on how to improve a building's energy efficiency.
Changes to be considered include:
We expect to assess more buildings using the Reference Building Verification Method, particularly with elevated timber floor.
For Class 2 and 4 buildings BCA2008 Part J applies to 1 May 2009:
either DTS2008 Parts J1 to J8, or Verification Method JV1 - 3 Stars minimum per Unit and DTS2008 Parts J5 to J8, with
For Class 3, 5 to 9 buildings BCA2008 Part J applies to 1 May 2009:
either DTS2008 Parts J1 to J8, OR Verification Method JV3 (Reference Building) and DTS Part J8.
A Reference Building is the same size, shape and location as the proposed building which complies with DTS in all elements. The Total Energy of the proposed building must be less than the Reference Building to comply. If any element of the proposed building does not comply with DTS (e.g. wall insulation or glazing) it must be better than DTS in other elements to compensate.
To cover additional information needed for the new assessment software (Residential and Commercial), we have a new Energy Efficiency Check List posted to www.clydeanderson.com.au/checklist.html, replacing the previous Check List. Please download the new version (Version 0903) to avoid us having to call you for more details.
We now supply the Check List in three different formats - MS Office 2003 *.DOC, OpenOffice.org *.ODT and Adobe Reader *.PDF. This allows you to fill it out and email it back to us. The current version is experimental and we are still checking it for compatibility in all versions of all common Office applications. If it does not work for you the PDF version is still available that can be faxed/mailed/scanned-and-emailed to us, as before. Let us know what you think as we want to make the Check List easy to use since it is an important part of our Quality Management System.
Finally, Clyde Anderson Pty Ltd has successfully completed an ISO9001 Quality Management System audit in Energy Efficiency Consulting. This means our consulting services have been audited by an independent auditor and achieve a high level of assured quality.